CALCULATOR · TOOL

555 Timer Calculator

Classic R1-R2-C astable circuit — compute frequency, period, and duty cycle.

Basic No backend · 100% client-side

What it does: Compute the frequency and duty cycle of the square wave from a 555 astable circuit.

When to use it: When building blinkers, buzzers, clock pulses, or starting out with PWM.

→ ≈687 Hz
Next

You might also need

Read the guide: NE555 pinout, specs & typical circuits

How to

How to use the 555 timer calculator

Enter R1, R2, C.

  1. 01

    Enter R1 and R2

    The two timing resistors in the classic astable circuit. Accepts 1k, 10k.

  2. 02

    Enter timing capacitor C

    The capacitor that sets the overall speed. Accepts 100n, 1u, 10uF.

  3. 03

    Read frequency and duty cycle

    Get the oscillation frequency f, period T, high/low times, and duty cycle.

Reference

Astable formulas

Standard formulas for the classic R1-R2-C circuit (using ln2 ≈ 0.693).

QuantityFormula
High time t_H0.693 × (R1 + R2) × C
Low time t_L0.693 × R2 × C
Period T0.693 × (R1 + 2·R2) × C
Frequency f1 / T
Duty cycle D(R1 + R2) / (R1 + 2·R2)

Standard NE555 astable formulas (classic datasheet circuit).

FAQ

Common questions, answered in 3 minutes

Why is the duty cycle always greater than 50%?

In the classic circuit the capacitor charges through R1+R2 but discharges only through R2, so the longer charge path makes the high time longer. To get ≤50% you need a diode to bypass R2, which is a different circuit.

How do I get a square wave close to 50%?

Make R1 much smaller than R2 (e.g. R1 in the 1Ω range, R2 large) so the duty cycle approaches 50%; or use the improved circuit with a diode.

The calculated frequency doesn't match my measurement?

Electrolytic capacitors have wide tolerance (±20% is common) and leakage also affects timing, so the actual frequency will deviate from the theoretical value. For accuracy, use a film capacitor and trim by measurement.

Is this astable or monostable?

This tool computes the astable mode (self-oscillating, continuously outputting a square wave). The monostable mode (one pulse per trigger) uses a different formula and may be added later.

Data Provenance

Standards and sources referenced by this tool

Item Value / Formula Source
Frequency f = 1.44 / ((R1 + 2·R2)·C) NE555 astable (datasheet)
Duty cycle D = (R1 + R2)/(R1 + 2·R2) NE555 astable (datasheet)

Standard NE555 astable formulas, no external API. The actual frequency is affected by capacitor tolerance/leakage and needs trimming by measurement.